Cosel ADA Series

  • High power, high peak current fan-less PFC power supply
  • Peak power is affordably attained without the expense of unnecessary functions
  • AC input range: 85~264vac (47~63Hz)
  • Operating temperature: -10~+71°C
  • Safety approvals: UL60950-1, C-UL(CSA60950-1) recognized, TUV approved, complies with DEN-AN
  • Wide output voltage adjustment range
  • Parallel operation, LED indicator for power on and current monitor
  • Protections: over current / over voltage / peak current / thermal
  • Available options: low leakage current, cooling fan unit (24 volt models only), vertical terminal block, conformal coating, remote On/Off, DIN rail mount, alarms and redundant operation
  • Cosel 5 year warranty
  • TRC Electronics is the USA stocking headquarters of Cosel ADA high peak current power supplies. Contact us for award winning service.
ADA power supply
Safety Logos
Cosel
Model#
Output
Voltage
Max.
Current
Peak
Current
Input
Voltage
Cooling
Method
ADA600F-24 24vdc 14A 25A 100vac Convection
21A 25A Forced Air
15A 31A 200vac Convection
25A 31A Forced Air
ADA600F-30 30vdc 11A 20A 100vac Convection
16.5A 20A Forced Air
12A 24.5A 200vac Convection
20A 24.5A Forced Air
ADA600F-36 36vdc 9A 16.5A 100vac Convection
14A 16.5A Forced Air
10A 20.5A 200vac Convection
16.5A 20.5A Forced Air
ADA600F-48 48vdc 6.5A 12.5A 100vac Convection
10.5A 12.5A Forced Air
7A 15.5A 200vac Convection
12.5A 15.5A Forced Air
  • Dimensions: 65mm x 127mm x 195mm
  • Additional Options(P/N Suffix)Low Leakage Current(G), Low Leakage Current and EMI Class A(E), with Fan Unit only -24(F), Vertical Terminal Block(T), Molex Connector(J), Conformal Coating(C), Remote On/Off(R), Din Rail(N1), Alarm and Redundant Operation(W).

Safety Logos
Cosel
Model#
Output
Voltage
Max.
Current
Peak
Current
Input
Voltage
Cooling
Method
ADA750F-24 24vdc 17A 42A 100vac Convection
25A 42A Forced Air
19A 63A 200vac Convection
31.5A 63A Forced Air
ADA750F-30 30vdc 13.5A 33.5A 100vac Convection
20A 33.5A Forced Air
15A 50A 200vac Convection
24.5A 50 Forced Air
ADA750F-36 36vdc 11A 28A 100vac Convection
16.5A 28A Forced Air
12.5A 42A 200vac Convection
20.5A 42A Forced Air
ADA750F-48 48vdc 8A 21A 100vac Convection
12.5A 21A Forced Air
9A 31.5A 200vac Convection
15.5A 31.5A Forced Air
  • Dimensions: 70mm x 127mm x 230mm
  • Additional Options(P/N Suffix)Low Leakage Current(G), Low Leakage Current and EMI Class A(E), with Fan Unit only -24(F), Vertical Terminal Block(T), Molex Connector(J), Conformal Coating(C), Remote On/Off(R), Din Rail(N1), Alarm and Redundant Operation(W).

Safety Logos
Cosel
Model#
Output
Voltage
Max.
Current
Peak
Current
Input
Voltage
Cooling
Method
ADA1000F-24 24vdc 21A 63A 100vac Convection
33A 63A Forced Air
25A 83A 200vac Convection
42A 83A Forced Air
ADA1000F-30 30vdc 16.5A 50A 100vac Convection
26A 50A Forced Air
20A 66A 200vac Convection
33.5A 66 Forced Air
ADA1000F-36 36vdc 14A 42A 100vac Convection
22A 42A Forced Air
16.5A 55A 200vac Convection
28A 55A Forced Air
ADA1000F-48 48vdc 10.5A 31.5A 100vac Convection
16.5A 31.5A Forced Air
11.5A 41.5A 200vac Convection
21A 41.5A Forced Air
  • Dimensions: 75mm x 127mm x 280mm
  • Additional Options(P/N Suffix)Low Leakage Current(G), Low Leakage Current and EMI Class A(E), with Fan Unit only -24(F), Vertical Terminal Block(T), Molex Connector(J), Conformal Coating(C), Remote On/Off(R), Din Rail(N1), Alarm and Redundant Operation(W).

Sales Questions?

Call: 1-888-612-9514

Business Hrs: Mon~Fri 8:00am~7:00pm EST



New Cosel Power Supplies
Cosel GHA500 500 Watt 3x6 Power Supply The GHA500F-SNF Series by Cosel is the highest power density 500W Power Solution! Only 3x6"!
GHA500F-12-SNF 12V@37.5A
GHA500F-15-SNF 15V@33.4A
GHA500F-24-SNF 24V@21A
GHA500F-30-SNF 30V@16.7A
GHA500F-48-SNF 48V@10.5A
GHA500F-56-SNF 56V@9A
LEARN MORE