How to Connect Power Supplies in Series: Series Stacking Made Simple
Engineers often face design requirements where a standard off-the-shelf power supply fails to deliver the necessary output voltage. You might need an uncommon potential like 72V or 96V to drive a specific motor controller, or standard high-voltage units might simply be too large or expensive for your enclosure.
In these situations, connecting standard, off-the-shelf power supplies in series is an effective, economical solution. Stacking two lower-voltage units allows you to reach target voltages while retaining familiar footprints. However, combining outputs isn't as simple as wiring positive to negative. Ignoring current matching, protection circuits, and isolation ratings can quickly result in fried components or electrical hazards.
This guide walks through the core mechanics of series operation, protective diode sizing, critical safety limits, control feature setups, and the alternative approach of modular configurable power supplies.
Some Modular Power Supplies are specifically designed to allow “easy” series connections. Here are a few which qualify:
The Fundamentals of Series Power Stacking
When you connect power supplies in series, the output voltages add together while the maximum current capability remains equal to the lowest-rated unit.
Voltage and Power Add while Current Is Constrained
Connecting two 48V, 5A (240W) power supplies in series yields a single 96V, 5A (480W) output system. Power adds across the total stack because the total output potential doubles while handling the same current flow.

Figure 1: Power supplies in series have their voltages and power added while the current limit stays the same.
Mixing supplies with different current limits creates a severe bottleneck. Consider a 48V, 5A (240W) unit wired in series with a 48V, 10A (480W) unit. The overall system yields 96V, but safe current capacity caps at 5A. The combined capacity is 480W, not 720W.
Attempting to draw more than 5A will force the smaller supply into overcurrent protection, potentially causing the entire stack to drop voltage unpredictably. To avoid unexpected shutdowns, always select identical power supply models with matched current ratings.
Series vs. Parallel Connections
- Series Configuration: Links the positive terminal of one supply to the negative terminal of the next. Output voltages add up while current capacity remains constant.
- Parallel Configuration: Connects positive-to-positive and negative-to-negative. Output current capability adds up while output voltage stays constant.
Both parallel configurations and series configurations increase total system wattage, but one increases available current, while the other increases output voltage.
Learn more about parallel connections and current sharing by visiting our blog:
Multiplying Your Power: When and How to Parallel AC/DC Power Supplies
Creating Dual Split-Rail Voltages (+/- Vout)
Series configurations allow you to create dual split-rail outputs (+V, Common, -V) for applications like audio amplifiers, sensitive analog front-ends, or operational amplifier (op-amp) rails.
To build a ±48V rail, wire two isolated 48V supplies in series. The junction point where the negative terminal of Supply B meets the positive terminal of Supply A becomes your System Common (0V). The remaining free positive terminal supplies +48V relative to Common, and the remaining free negative terminal supplies -48V relative to Common. Most switching power supplies with isolated outputs can be used as either positive or negative voltage sources.

Figure 2: Power supplies in series where the connection between the supplies is used as a common reference will create split rails of +/- Vout.
Protecting The Circuit: Reverse Bypass Diodes
Wiring power supplies in series introduces a hidden danger during start-up, shut-down, or fault conditions: reverse voltage stress.
The Mechanism of Output Damage
Power supply outputs rarely turn on at the exact same millisecond. If Supply B powers up faster than Supply A, or if Supply A enters overcurrent shutdown, Supply B will continue driving current through the load.
With Supply A turned off, its active switching devices are inactive. To complete the circuit back to Supply B, the system current forced by Supply B must pass directly through Supply A's unpowered output terminals.
While the current continues moving in its normal loop direction, forcing current through an unpowered supply from Negative (-) to Positive (+) causes the power supply to act like a load, which reverses the voltage potential across its terminals (V(+) < V(-)).

Figure 3: Series power supplies risk turning one supply into a load when one unit is on and the other is off (such as during a mis-timed start up sequence.)
This reverse voltage polarity will be directly across the power supply’s polarized output capacitors. Standard electrolytic output capacitors cannot handle reverse voltage. Sustained reverse voltage of more than about 1 V quickly degrades or destroys electrolytic capacitors.
Connecting a diode across each supply's output terminals in a “reverse-biased” orientation, prevents this damage by limiting reverse voltage and by providing a safe, low-resistance bypass path for fault current around the inactive unit.

Figure 4: Reverse-biased diodes across the output of series power supplies offer reverse voltage limit protection and an alternate current path.
Protection Diode Installation and Sizing
Diodes should be connected directly across the output terminals of every supply in the stack. The cathode of each diode should be connected to the positive output terminal, and the anode should be connected to the negative output terminal. Under normal operation, the diode is reverse-biased and draws no current. If one unit turns off or lags behind, the bypass diode conducts, clamping the reverse voltage across that unit to a safe level (around 0.3V to 1.0V) while offering a bypass path for system current.
Follow these rules when sizing bypass diodes:
- Current Rating: The diode must handle a continuous forward current equal to or greater than the maximum current potential of the power supply stack. Note that this will often be linked to the over current protection limit, not the PSU current rating!
- Reverse Voltage Rating (VRRM): The diode's reverse voltage rating should exceed the total combined voltage of the complete series stack, not just the single unit it spans. This is particularly important if the load has a capacitive or generative nature, because if one or more PSUs shut down, almost the entire load voltage will temporarily be across the remaining diodes.
- Diode Type: Use Schottky diodes for lower clamping voltage to keep forward voltage drops minimal and for fast turn on times. For higher voltage stacks, high-speed recovery diodes are ideal.
Note: Check your product datasheet or installation manual before adding external hardware. Certain industrial power supplies and configurable modular units include internal reverse-bias protection diodes.
Isolation and Safety Limits
Not every power supply can be wired in series. Stacking outputs depends entirely on electrical isolation ratings and local safety standards.
Output-to-Chassis Ground Isolation
For series stacking to work safely, each individual output must be floating, meaning isolated from both the AC input line and Frame Ground (FG).
Exceeding the rated Output-to-FG Isolation Voltage is a common mistake. As you stack units, the total potential between the highest output rail and chassis ground increases. If your stack voltage exceeds the output-to-ground breakdown rating, electrical arcing can occur through the insulation barrier to the metal chassis.
The datasheet will sometimes have both of the following ratings:
- Withstand Voltage (Isolation Voltage): The maximum AC or DC voltage the insulation barrier withstands for 60 seconds without breakdown.
- Isolation Resistance: The internal resistance of the isolation barrier, typically measured in Megohms (MΩ) using a high-voltage DC test.
It is the withstand voltage here that will provide a suggestion of the highest voltage you can safely have from a series connection. Note however that these isolation/withstand tests are often only for 60 seconds. True series voltage maximums should be verified and/or a safety margin implemented.
Note that isolation ratings are generally based on a 60 second withstand voltage test. Contact TRC Electronics to discuss your series application and confirm series connection limits.
1-888-612-9514
SELV / ES1 Limits and Safety Approvals
Under safety standards such as IEC/EN 62368-1, DC voltages up to 60VDC fall under ES1 limits (comparable to Safety Extra Low Voltage [SELV] under the older IEC 60950-1). These circuits require minimal touch protection and simplified insulation barriers.
- Note that exceeding these limits can result in additional protection or certification requirements for your end system.
Control Signals and Feature Setup
Using advanced functions like remote sensing, output trimming, or control signals requires extra caution when supplies are wired in series.
Remote Sense Wiring
Remote sensing compensates for voltage drops along output cables by sampling voltage directly at the load. Attempting to measure across the entire stack may create instability. Remote sense would only work if the series connections are being made at the point of load.
Voltage Programming
Many voltage programming pins are referenced to the -Vout of the supply. Trying to program series connected power supplies from the same source can create a short circuit condition! If attempting external voltage programming on series units, use opto-isolated programming signals.
DC OK and Power Good Signals
Many power supplies offer "DC OK" or "Power Good" logic signals to monitor status. Before tying these signal lines to a central microcontroller, confirm whether the signals share a return path with the output's negative terminal (-Vout). As with the programming pins, opto-isolation is the best way to avoid accidental shorting with these signals.
The Cleaner Alternative: Modular Configurable Power Supplies
Manually wiring separate single-output power supplies in series introduces multiple point-of-failure risks: extra cabling, loose diode mounts, separate enclosure footprints, and multiple AC leakage paths.
Modular configurable power supplies solve these issues by placing multiple isolated DC output modules inside a single chassis fed by a single AC input.
Benefits of Modular Configurations
- Integrated Isolation: Modules built for series configuration feature output-to-ground isolation ratings designed specifically for stacking.
- Fewer External Components: Some modular platforms incorporate reverse-bias protection inside each module, eliminating external bypass diodes.
- Simplified Compliance: The complete assembly carries single-source safety agency approvals, streamlining end-system certification.
- Reduced Leakage Current: Powering multiple outputs from a single AC front-end keeps earth leakage currents far lower than using multiple individual power supplies.
Platforms like the Vox NEVO+ series, Vox VCCM series, Inission RCB/MCB series, or MEAN WELL NMP series feature output modules that are stacked next to each other and can be quickly linked in series using busbars that have been designed for precisely that purpose.

Figure 5: NMP1K2 chassis and close up view of series connections being made using MEAN WELL NMP series bars.
| Modular Product Selection OverviewPower levels, output voltage ranges, and key specifications by series | |||
| Brand / Family | Power Levels | Output Module Voltage Range | Series Notes |
|---|---|---|---|
| Vox NEVO+ | 600W and 1200W chassis available | 1.5V – 58V per module | Very small footprint. Separate chassis for industrial and medical. 250 Vdc isolation. 150W per module. |
| Vox VCCM | 600W per chassis | 1.5V – 58V per module | Conduction cooled modular series designed for fanless configurations. 500 Vdc isolation. 150W per module. |
| Inission RCB / MCB | 600W and 1200W chassis available | 1.5V – 58V per module | High-density modular family. Separate chassis for industrial and medical. 250 Vdc isolation. 150W per module. |
| MEAN WELL NMP | 650W and 1200W chassis available | 3V – 55V per module | Slightly larger chassis with higher power per module. Industrial and medical certifications in one chassis. 500 Vac isolation. 240W per module. |
Table 1: Modular Product Selection Overview
Video Reference
Check out this video by the TRC Electronics VP of Engineering where he discusses using power supplies in series!
Frequently Asked Questions
Can I connect two power supplies in series to double the voltage?
Yes. Wiring two identical, floating power supplies in series doubles the total output voltage while maintaining the single unit's current rating.
Do I need diodes when connecting power supplies in series?
Yes, when using standard single-output supplies. Reverse biased bypass diodes across each output prevent a power supply from becoming a load if that supply powers up more slowly or enters protection mode. Modular configurable systems sometimes integrate this protection internally.
Can I put power supplies with different voltages in series?
It is generally recommended to use only power supplies with the same ratings; however as long as their current ratings match, the configuration should work. For example, a 12V 5A supply and a 24V 5A supply wired in series will provide 36V at 5A.
What is the maximum voltage I can reach by stacking power supplies?
Maximum voltage is limited by the Output-to-Frame Ground (FG) Isolation Rating of the individual power supplies. Always confirm that this is a continuous rating. Generally this is the maximum voltage limit. However a +/-Vout configuration with a common ground can potentially allow a system to exceed this limit. A safety margin should always be employed also.
Is it better to stack individual supplies or use a modular power supply?
Modular supplies are generally superior when practical for the project budget. They eliminate external diodes, reduce interconnect wiring, lower total AC leakage current, and provide factory-tested compliance under a single safety approval. Note that not all modular power supplies are designed to allow series connections. The ones discussed in this article are.
Need Help Designing Your Power System?
Putting power supplies in series requires careful balance between system safety, isolation limits, and proper protection components. If you are designing custom high-voltage rails or evaluating modular alternatives, contact the engineering team at TRC Electronics, or call us at 1-888-612-9514. Our power specialists will help configure, test, and deliver a power solution optimized for your exact voltage and power requirements.
Written by: Thomas Denny | Applications Engineering Department | TRC Electronics
References
- TRC Electronics, "Inission MCB1200 Datasheet," TRC Electronics, [Online]. Available: https://files.trcelectronics.com/datasheets/MCB1200.pdf
- TRC Electronics, "Vox NEVO+1200M Datasheet," TRC Electronics, [Online]. Available: https://files.trcelectronics.com/datasheets/nevo1200m.pdf
- TRC Electronics, "Vox VCCM600M Datasheet," TRC Electronics, [Online]. Available: https://files.trcelectronics.com/datasheets/vccm600m.pdf
- TRC Electronics, "MEAN WELL NMP Series Datasheet," TRC Electronics, [Online]. Available: https://files.trcelectronics.com/datasheets/nmp.pdf
- IEEE 802.3, "ES1 vs LPS vs SELV," IEEE 802.3, [Online]. Available: https://www.ieee802.org/3/ad_hoc/PDCC/public/2021/ES1_LPS_SELV_1_0821.pdf.
Last Updated: [November 24, 2026]